¢Ã Milliamp Source
|
Ranges |
0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20
mA |
Accuracy |
Quik-Chek 4mA ¡¾(0.03% of 4mA + 0.01 mA) =
0.011mA Quik-Chek 20mA ¡¾(0.03% of 20mA + 0.01 mA) = 0.016mA 0 to 24mA
¡¾(0.05% of Reading + 1 LSD) |
Typical Drive Capability |
1200 Ohms @20.00 mA with fresh batteries, 800 Ohms @
20.00 mA with low batteries |
Compliance |
Nominal 27 VDC @20 mA with fresh
batteries |
¢Ã Power & Measure 2-wire
Transmitters |
Ranges |
0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20
mA |
Accuracy |
Quik-Chek 4mA ¡¾(0.03% of 4mA + 0.01 mA) =
0.011mA Quik-Chek 20mA ¡¾(0.03% of 20mA + 0.01 mA) = 0.016mA 0 to 24mA
¡¾(0.05% of Reading + 1 LSD) |
Output Current |
Up to 24.00 mA |
Typical Drive Capability |
1200 Ohms @20.00 mA with fresh batteries, 800 Ohms
@20.00 mA with low batteries |
Compliance |
Nominal 27 VDC @20 mA with fresh
batteries |
¢Ã 2-wire Transmitter Simulator
|
Ranges |
0.00 to 24.00 mA; -25.0 to 125.0 % of 4 to 20
mA |
Accuracy |
Quik-Chek 4mA ¡¾(0.03% of 4mA + 0.01 mA) =
0.011mA Quik-Chek 20mA ¡¾(0.03% of 20mA + 0.01 mA) = 0.016mA 0 to 24mA
¡¾(0.05% of Reading + 1 LSD) |
Loop Voltage Limits |
Minimum: 2
VDC Maximum:
100 VDC |
Overload Protection |
Current limited to 25 mA nominal |
¢Ã Milliamp Read |
Ranges |
0.00 to 52.00 mA; -25.0 to 300.0 % of 4 to 20
mA |
Accuracy |
Quik-Chek 4mA ¡¾(0.03% of 4mA + 0.01 mA) =
0.011mA Quik-Chek 20mA ¡¾(0.03% of 20mA + 0.01 mA) = 0.016mA 0 to 24mA
¡¾(0.05% of Reading + 1 LSD) |
Voltage Burden |
0.9V at 4 mA, 1.2V at 20 mA, 1.9V at 50 mA excitation
current |
¢Ã Read DC Volts |
Range |
-99.99 to 99.99V DC |
Input Impedance |
>2 Meg Ohms |
¢Ã General |
Accuracy |
Quik-Chek 4 & 20 mA ¡¾(0.03% of Setting + 1
LSD) Milliamp & % Ranges ¡¾(0.05% of Reading + 1 LSD) Read DC Volts
¡¾(0.05% of Span + 1 LSD) |
Warm up Time |
10 Seconds to specified accuracy, 2 minutes to maximum
accuracy |
Temperature Effect |
Milliamp Ranges:
¡¾0.008% of Reading/¡ÆC Read DC
Volts: ¡¾0.012% of Span/¡ÆC |
Batteries |
Three 9V, (1604) batteries (Alkaline supplied and
recommended) |
Battery Life |
Source and Power Transmitter: Nominal 33 hours at 12 mA, 20 hours at 20 mA with 250 ohm
load Read mA, DC V & 2-wire
Simulate: Nominal 100 hours |
Low Battery Indication |
"BAT" indication on the display at approximately 4 hours
left |
Overvoltage Protection |
Protected to 135V AC/DC for 30 seconds without
fuses |
Operating Temperature Range |
-5 to +140 ¡ÆF (-20 to +60¡ÆC) |
Storage Temperature Range |
-22 to +160 ¡ÆF (-30 to +70¡ÆC) |
Relative Humidity |
10 to 90%, non-condensing for 24 hours from 0 to
35¡ÆC |
Dimensions |
121.9mm (4.8 in) x 66mm (2.6 in) x 35.8mm (1.41
in) |
Weight |
7.8oz
(0.22kg) |